Fire testing of RC beams strengthened with NSM reinforcement

机译:利用NSM加固强化RC梁的火灾测试

获取原文

摘要

The weak performance of fibre reinforced polymer (FRP) strengthened members in fire is a primary factor hindering the widespread implementation of FRP strengthening technology in the construction industry. An investigation was undertaken to examine and document the performance of NSM FRP strengthened concrete beams under fire conditions. Six reinforced concrete beams were strengthened in flexure with NSM FRP bars and insulated with different insulation systems. The specimens were subsequently exposed to a standard fire under service load. The testing parameters of these elements include the use of different thermal protections (including different materials and geometric layouts of the protection) of the glued reinforcement. Member deflections and temperatures throughout the section were measured during fire testing. Tests results indicated that insulated NSM FRP strengthened beams can achieve a fire endurance of at least of two hours.
机译:纤维增强聚合物(FRP)强化成员在火灾中的弱表现是妨碍了建筑业FRP强化技术的主要因素。开展了调查,审查并记录了在火灾条件下的NSM FRP强化混凝土梁的表现。用NSM FRP棒强化六个钢筋混凝土梁,并用不同的绝缘系统绝缘。随后将标本暴露于载荷负荷下的标准火灾。这些元件的测试参数包括使用胶合加固的不同热保护(包括保护的不同材料和几何布局)。在防火测试期间测量整个部分的成员偏转和温度。测试结果表明,绝缘NSM FRP强化梁可达到至少两小时的火灾耐力。