The use of near surface mounted (NSM) fiber reinforced polymers (FRPs) is being increasingly recognized as a valid technique strengthening of concrete members. In case of elevated temperature or fire exposure however, the bond between the bars and the concrete will be lost very quickly due to the adhesive's low glass transition temperature. Although recent studies have shown that the fire endurance of appropriately designed and insulated FRP strengthened RC members is satisfactory, the performance of FRP strengthening systems at high temperature remains largely unknown. To study the bond behaviour at elevated temperature between the NSM FRP bars and concrete a series of 18 double bond shear tests were performed at Ghent University Results show that the failure load of NSM FRP strengthened concrete structures and the bond strength are influenced at values of temperature equal to or beyond the glass transition temperature. Failure mode changed by increasing the temperature.
机译:使用近表面安装(NSM)纤维增强聚合物(FRPS)的使用越来越普遍认为是混凝土构件的有效技术。在温度或火灾曝光升高的情况下,由于粘合剂的低玻璃化转变温度,条形和混凝土之间的粘合将损失很快。尽管最近的研究表明,适当设计和绝缘FRP的防火耐力加强了RC成员令人满意,但高温下FRP强化系统的性能仍然很大程度上是未知的。为了研究NSM FRP和混凝土之间的升高温度下的债券行为,在根特大学进行一系列18双键剪切试验表明,NSM FRP强化混凝土结构的故障负载和粘合强度受到温度值的影响等于或超出玻璃化转变温度。失效模式通过增加温度来改变。