In accordance with German nuclear regulations, a seismic PSA (SPSA) was performed on Kernkraftwerk Neckarwestheim Unit 2 (GKN II), a PWR located in Germany near Stuttgart. The study was conducted using techniques that comply with both German PSA guidelines and the ANS (now ASME/ANS) standard requirements for SPSA. The study found that the seismic design of the plant is quite high given the seismic hazard at the site. As a result, seismic core damage frequency contributes approximately 1% to total core damage risk of the plant. The risk is dominated by seismically-induced plant shutdown (no loss of offsite power) followed by random failures and human errors, and the dominant seismic events are at the low end of the hazard curve. The results are essentially insensitive to most seismic-related inputs, but are sensitive to the human error probabilities used. The walkdown did indentify few housekeeping items that could compromise the seismic performance of a few components, which the plant is addressing.
机译:根据德国核法规,对位于德国斯图加特附近的压水堆Kernkraftwerk Neckarwestheim 2号机组(GKN II)进行了地震PSA(SPSA)。这项研究是使用既符合德国PSA指南又符合SPSA的ANS(现在为ASME / ANS)标准要求的技术进行的。研究发现,考虑到现场的地震危险性,该工厂的抗震设计相当高。结果,地震核心损坏频率约占工厂总核心损坏风险的1%。风险主要由地震引起的工厂停工(无现场电源损失),随后的随机故障和人为失误控制,主要的地震事件位于危险曲线的低端。结果对大多数与地震相关的输入基本上不敏感,但对所使用的人为错误概率敏感。这次罢工确实确定了一些可能损害工厂正在解决的某些部件的抗震性能的内务处理项目。