首页> 外文会议>FLOMEKO 2010;International flow measurement conference >Installation Effects of Ultrasonic Flowmeter in Single Bend Pipe
【24h】

Installation Effects of Ultrasonic Flowmeter in Single Bend Pipe

机译:超声波流量计在单弯管中的安装效果

获取原文

摘要

The downstream flow of 90°single bend was investigated by computational fluid dynamics (CFD). An acoustic transit time flowmeter was exposed to the downstream flow at various positions. Measurement errors with different meter configurations and effects of pipe wall roughness were discussed. Numerical simulation results of three diameter pipes 0.1m, lm and 10m with increasing the roughness from 0 to lmm were presented within Reynolds number (Re) range from 5x 103 to 5xlO6.
机译:通过计算流体动力学(CFD)研究了90°单弯管的下游流动。声波传播时间流量计在各个位置暴露于下游流量。讨论了不同仪表配置下的测量误差以及管壁粗糙度的影响。在从5x 103到5x106的雷诺数(Re)范围内,将粗糙度从0增大到1mm的三个直径为0.1m,lm和10m的管道的数值模拟结果进行了介绍。