A 2" NB Critical Flow Venturi Nozzle (CFVN) of Nominal Flow capacity 25m3/h was designed at Fluid Control Research Institute (FCRI), India as a transfer standard for undertaking calibration of smaller capacity flow meters. The Nozzle fabricated was of Toroidal throat design and was assembled as per the general guidelines of ISO 9300:2005 "Measurement of gas flow by means of Critical flow Venturi nozzles". The Air Flow Measurement facilities at FCRI is equipped with Primary Standards Pressure-Volume-Temperature-time (PVTt) facility of 2m3 Nominal volume and 90 m3/h maximum flow capacity and a Bell Prover of 500 ltr volume and with a maximum flow capacity of 40m3/h. The performance of the Critical Flow Venturi Nozzle assembly was tested and analyzed with both PVTt facility and Bell Prover. PVTt facility can be used as a collection tank for estimation of mass flow rate during operation of CFVN during suction mode.To establish dynamic traceability in measurements and compare the test results with other proven primary standards, the same CFVN assembly was calibrated both under pressure mode and suction mode using the Primary standard Bell Prover system available at the Primary Standard Air Flow Laboratory at FCRI. During filling mode operation of Bell Prover, the Throat Reynolds number of nozzle was about 1.24E+05 and in Discharge mode of flow test the Throat Reynolds number of nozzle was about 8.61E+04.Cd of the nozzle was established at different Reynolds numbers with both PVTt facility and Bell prover. The results obtained with the above methods were validated using ISO equation given in ISO 9300: 2005.
机译:印度流体控制研究所(FCRI)设计了额定流量为25m3 / h的2“ NB临界流量文丘里喷嘴(CFVN),作为对较小容量流量计进行校准的传输标准。喷嘴由环形喉制成设计并根据ISO 9300:2005“通过临界流量文丘里喷嘴测量气体流量”的一般准则进行组装。标称容积为2m3,最大流量为90 m3 / h的设施,容积为500 ltr,最大流量为40m3 / h的Bell Prover。临界流量文丘里喷嘴组件的性能已通过PVTt设施和Bell Prover。PVTt设施可用作收集罐,用于在吸气模式下操作CFVN时估算质量流量。建立测量的动态可追溯性并比较测试结果与其他公认的主要标准一起,使用CFRI的主要标准气流实验室提供的主要标准Bell Prover系统,在压力模式和吸气模式下对相同的CFVN组件进行了校准。在Bell Prover的填充模式操作期间,喷嘴的喉雷诺数约为1.24E + 05,在流量测试的排出模式下,喷嘴的喉雷诺数约为8.61E + 04。在不同的雷诺数下确定了喷嘴的Cd同时拥有PVTt设施和Bell证明者。使用ISO 9300:2005中给出的ISO公式验证了通过上述方法获得的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号