Soft tissue simulants are used in ballistic testing as a tool for capturing the interaction projectiles have with living tissue. No internationally agreed standard exists for the preparation of such tissue simulants; a factor that has led to questions regarding reliability and reproducibility of results presented in the open literature. A calibration method for 10 % gelatine has been suggested utilising low velocity projectiles [1]. However, recent work has suggested that gelatine is strain rate sensitive [2]. Therefore it may be more appropriate to test at velocities representative of the projectile under investigation. This paper presents a modified method to assess the differences in penetration depth in three simulants. Non-deformable ball bearings (BBs) of similar diameter to ammunition of interest (5.5 mm BBs, 5.56 mm × 45 mm) at a range of velocities representative of different engagement ranges (150 m/s, 250 m/s, 500 m/s, 750 m/s and 1050 m/s) were used.
机译:软组织模拟剂用于弹道测试作为捕获相互作用射弹的工具,具有活组织。不存在国际商定的标准,用于制备这种组织模拟剂;一个因素导致了开放文学中呈现的结果的可靠性和再现性的问题。已经利用低速射弹进行了10%明胶的校准方法[1]。然而,最近的工作表明明胶是应变率敏感[2]。因此,在调查下的射弹速度下测试可能更适合于测试。本文提出了一种改进的方法,用于评估三种模拟中的渗透深度差异。在代表不同接合范围的一系列速度(150m / s,500 m /)的速度范围内与弹药(5.5mm bbs,5.56 mm×45mm)相似直径的不可变形的滚珠轴承使用S,750 m / s和1050 m / s。