A typical prosthetic limb has sensory shortcomings, one of which is lack of kinesthesia. Conventional methods to evoke kinesthesia, which would be required for a precise control of prosthetic limbs, include tendon vibration and skin stretch, but these produce only the sensation of small movements. In this study, tendon vibration is extended to evoke sensations of a more rapid movement. A stimulation method in which vibration is applied to two tendons is proposed, in contrast to most studies in which a single tendon was vibrated. Experimental results indicated that vibration applied to both ends of a muscle produces sensations of more rapid movement than vibration to just one. However, no significant difference in sensation was found between vibrating tendons of synergistic muscles and a single tendon.
机译:典型的假肢有感觉缺陷,其中之一是缺乏运动感觉。精确控制假肢需要传统的诱发运动感觉的方法,包括肌腱振动和皮肤拉伸,但这些方法只会产生微小运动的感觉。在这项研究中,肌腱振动被扩展以唤起更快运动的感觉。与大多数研究单个肌腱振动的研究相反,提出了一种将振动施加到两个肌腱的刺激方法。实验结果表明,施加到肌肉两端的振动会产生比仅施加一个振动更快的运动感觉。但是,在增效肌肉的振动肌腱和单个肌腱之间没有明显的感觉差异。