Amorphous metal core dry-type distribution transformers have a significant place in today power market since they exhibit 60–70% lower no-load losses when compared to the standard steel based transformers. At typical loading regimes these losses are the most significant ones for a distribution transformer. In order to improve the design and to shorten significantly the time to market of such products numerical analysis of the no-load as well as of the load tests are of paramount importance. The present manuscript describes the FEM based numerical analysis performed on a 1 MVA unit, in an industrial environment, with the emphasis on the importance of non-linear and anisotropic magnetic modeling as opposed to isotropic for the accurate computation of no-load losses. The choices for the analysis regime and the specific analysis tools are described in details - and results are given to prove the salient points of this particular design of a transformer.
机译:非晶金属芯干式配电变压器在当今的电力市场中占有重要地位,因为与标准的钢基变压器相比,它们的空载损耗降低了60%至70%。在典型的负载状态下,这些损耗对于配电变压器而言是最严重的损耗。为了改善设计并显着缩短此类产品的上市时间,对空载以及载荷测试进行数值分析至关重要。本手稿描述了在工业环境中在1 MVA单元上执行的基于FEM的数值分析,重点是非线性和各向异性磁建模的重要性,而不是各向同性对于精确计算空载损耗的重要性。详细介绍了分析方案和特定分析工具的选择-并给出了结果来证明这种特殊设计的变压器的要点。