The unbalanced magnetic forces which act upon the rotor of a salient-pole synchronous generator due to eccentric motion of the rotor shaft in the presence of magnetic field originating from the field current in no-load operation have been calculated using finite-element method. The displacement of the rotor has been modeled using the actual shaft orbit recorded on a 5 MVA salient-pole generator driven by a gas turbine in a cogeneration plant. The results indicate that a variation of unbalanced forces in no-load operation at rated voltage occurs at the precession frequency of 25 Hz with maximum force of 2.32 kN.
机译:使用有限元方法已经计算出了在空载运行中磁场电流产生的磁场的作用下,由于转子轴的偏心运动而导致的作用在凸极同步发电机转子上的不平衡磁力。转子的排量已使用热电联产电厂中由燃气轮机驱动的5 MVA凸极发电机上记录的实际轴轨迹进行建模。结果表明,在进动频率为25 Hz,最大力为2.32 kN的情况下,在额定电压下的空载运行中,不平衡力会发生变化。