A sensitive and fast analytical method using purge-and-trap (P&T) on-line coupling with gas chromatography was developed for the determination of four trace volatile halohydrocarbons including methylene, chloroform, carbon tetrachloride and trichloroethylene in water. The analytes were purged for 10min from the sample by high purity nitrogen and preconcentrated in the cooled trap at -80 degC . The halohydrocarbons were separated with an gas chromatograph by a suitable temperature program and detected by means of a mass spectrometer using selected ion monitoring (SIM). The detection limits were found to be in the range of 0.0008 to 0.02mug/L, the relative deviations ranged from 1.9% to 5.4%, the recovery ratios ranged were 89% to 104%, The linearity ranges of 4 compounds were in the range of 0.001 to 50mug/L, with correlation coefficients from 0.9991 to 0.9997. The method is fast, sensitive, simple. It has better accuracy and precision in determination of these halohydrocarbons in water compared with the traditional method.
机译:建立了一种使用吹扫捕集(P&T)在线与气相色谱联用的灵敏,快速的分析方法,用于测定水中的四种痕量挥发性卤代烃,包括亚甲基,氯仿,四氯化碳和三氯乙烯。用高纯度氮气将样品中的分析物吹扫10分钟,然后在-80℃的冷阱中进行预浓缩。用气相色谱仪通过合适的温度程序分离卤代烃,并通过质谱仪使用选定的离子监测(SIM)进行检测。检出限为0.0008至0.02mug / L,相对偏差为1.9%至5.4%,回收率为89%至104%,4种化合物的线性范围为0.001至50 ug / L,相关系数从0.9991至0.9997。该方法快速,灵敏,简单。与传统方法相比,它在测定水中这些卤代烃方面具有更高的准确度和精密度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号