首页> 外文会议>Human Factors and Ergonomics Society annual meeting;HFES 2008 >Methodological Considerations for Using the English XL Tribometer for Post Hoc Slip-and-Fall Evaluations
【24h】

Methodological Considerations for Using the English XL Tribometer for Post Hoc Slip-and-Fall Evaluations

机译:使用英语XL摩擦计进行事后滑倒和跌落评估的方法学考虑

获取原文

摘要

We examined several variables that can affect slip-resistance measurements obtained using the English XL tribometer to illustrate the importance of implementing the proper controls when using the device to evaluate a slip-and-fall incident. We measured slip resistance at two different locations on the same surface, under wet and dry conditions, with the tribometer oriented in eight different directions per location. Our results showed that location, direction, and surface wetness can affect slip resistance measurements, but the effects interact with each other in unpredictable ways. Discussion focuses on the importance of considering direction as well as location of a particular slip-and-fall, rather than strict adherence to ASTM F1679-04: Standard Test Method for Using a Variable Incidence Tribometer (VIT). We conclude that it is important to consider both location and direction when using the tribometer in analysis of any specific incident occurring on non-uniform surfaces.
机译:我们检查了一些会影响使用英式XL摩擦计获得的防滑性能测量值的变量,以说明在使用该设备评估滑倒事件时实施适当控制的重要性。我们在潮湿和干燥条件下,在同一表面上的两个不同位置测量了防滑性能,每个位置的摩擦计朝向八个不同方向。我们的结果表明位置,方向和表面湿度会影响防滑性能的测量,但这些效果会以不可预测的方式相互影响。讨论的重点是考虑特定滑移的方向和位置的重要性,而不是严格遵守ASTM F1679-04:使用可变入射摩擦计(VIT)的标准测试方法。我们得出结论,在使用摩擦计分析不均匀表面上发生的任何特定事件时,必须同时考虑位置和方向。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号