This paper represents the VHF/UHFpartial discharge measurement technique compared with conventional partial discharge measurement method, IEC 60270. The artificial partial discharge objects which represent corona discharge, internal discharge, and surface discharge, were set up and tested with the mention techniques. The test results show that three kinds of partial discharge give obviously different frequency signal obtained from vertical and horizontal VHF/UHF antenna. Its amplitude also depends on electric field stress of the test objects. Moreover the partial discharge activities of all kinds of test object obtained from conventional method are different. From the test results, it was found that unconventional partial discharge measurement technique, VHF/UHF method, can be an effective choice for partial discharge measurement. It also can be improved for online monitoring of insulation system in the future.
机译:与常规的局部放电测量方法IEC 60270相比,本文代表了VHF / UHF局部放电测量技术。使用上述技术建立并测试了代表电晕放电,内部放电和表面放电的人工局部放电对象。测试结果表明,三种局部放电产生的垂直和水平VHF / UHF天线的频率信号明显不同。其幅度还取决于测试对象的电场应力。而且,通过常规方法获得的各种测试对象的局部放电活性是不同的。从测试结果发现,非常规的局部放电测量技术,VHF / UHF方法,可以作为局部放电测量的有效选择。将来也可以对其进行改进,以进行绝缘系统的在线监控。