Single-node SOR Method for statistical 3D thermal analysis

机译:统计3D热分析的单节点SOR方法

获取原文

摘要

As the first study on Statistical 3D thermal analysis,we propose an efficient method for fewer over-hot spots. The new method,called SN-SOR (single-node SOR),is based on a novel localized relaxed iterative approach and it can perform statistical analysis on one over-hot spot at a time. Experiments show that SN-SOR is 590X faster than Monte-Carlo method with small errors and is 29X faster than general global SOR(successive over relaxation) method in statistical analysis of 450 over-hot spots. As a result,SN-SOR only take average 0.1481 second to statistically analyze one over-hot spot for a large test case of 1.3M nodes under spatially correlated energy and thermal conductance disturbances.
机译:作为统计3D热分析的第一项研究,我们提出了一种减少过热点的有效方法。这种称为SN-SOR(单节点SOR)的新方法基于一种新颖的局部松弛迭代方法,并且可以一次对一个热点进行统计分析。实验表明,在450个过热点的统计分析中,SN-SOR比Monte-Carlo方法快590倍,误差很小,比一般的全局SOR(连续过度松弛)法快29倍。结果,对于空间相关的能量和热导扰动下的1.3M节点的大型测试案例,SN-SOR仅花费平均0.1481秒来统计分析一个过热点。