首页> 外文会议>International Conference on Optical Fibre Sensors >In-situ temperature calibration procedure for temperature and strain fibre Bragg grating sensors for monitoring pre-stressing strands
【24h】

In-situ temperature calibration procedure for temperature and strain fibre Bragg grating sensors for monitoring pre-stressing strands

机译:用于监测预应力股线的温度和应变光纤布拉格光栅传感器的原位温度校准程序

获取原文

摘要

In this work, we demonstrate active and passive methods for in-situ temperature calibration of fibre Bragg grating strain and temperature sensors. The method is suitable for characterizing sensors which are already attached to the steel reinforcements of civil structures. The proposed method, which involves the use of active induction heating or passive room temperature fluctuations, can be implemented using portable equipment, is time efficient, and can be used to calibrate attached sensors on-site, rather than in lab conditions. Preliminary results of the induction heating calibration show good agreement with pre-calibrated temperature sensors. In-situ calibration of fibre strain sensors, attached to a prestressing strand is also successfully carried out.
机译:在这项工作中,我们展示了用于纤维布拉格光栅应变和温度传感器的原位温度校准的主动和被动方法。该方法适用于已经连接到公用结构的钢筋的传感器。可以使用便携式设备实现涉及使用有源感应加热或无源室温度波动的所提出的方法,该方法可以使用便携式设备来实现,并且可用于校准现场附加的传感器,而不是实验室条件。感应加热校准的初步结果与预校准的温度传感器显示出良好的一致性。还成功地进行了附着在预应力股线上的纤维应变传感器的原位校准。