Stator insulation quality assessment is an important issue for PWM inverter-fed machines, since the stator insulation is exposed to increased thermal/electrical stresses. In this paper, a new approach for monitoring the condition of the stator insulation for inverter-fed machines is proposed. The main concept of the proposed approach is to apply various types of test voltages to the motor stator insulation using the inverter, to perform standard off-line insulation tests whenever the motor is not operating. Two methods for testing the insulation with modifications to the inverter circuit are proposed and verified experimentally. The results show that the proposed technique provides a simple low cost solution for detecting stator insulation degradation at an early stage for reliable operation of inverter-fed machine systems, since the insulation condition can be monitored frequently. This not only helps prevent forced outages and safety risks due to insulation breakdown, but also helps perform maintenance in an efficient manner since individual motor maintenance can be prioritized and scheduled based on its present condition.
机译:定子绝缘质量评估对于PWM逆变器供电的电机来说是一个重要的问题,因为定子绝缘承受着增加的热/电应力。本文提出了一种监测逆变器馈电定子绝缘状况的新方法。提出的方法的主要概念是使用逆变器将各种类型的测试电压施加到电机定子绝缘上,以便在电机不运行时执行标准的离线绝缘测试。提出了两种通过对逆变器电路进行修改来测试绝缘的方法,并进行了实验验证。结果表明,所提出的技术提供了一种简单的低成本解决方案,可以在早期阶段检测出定子绝缘退化,从而使逆变器供电的机器系统可靠运行,因为可以经常监测绝缘状况。这不仅有助于防止由于绝缘故障而导致的强制性停电和安全风险,而且还可以有效地执行维护,因为可以根据电动机的当前状态确定优先级并安排单个电动机的维护工作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号