首页> 外文会议>IEEE Power Electronics Specialists Conference >A stator winding insulation condition monitoring technique for inverter-fed machines
【24h】

A stator winding insulation condition monitoring technique for inverter-fed machines

机译:逆变器送料机定子绕组绝缘条件监控技术

获取原文

摘要

Stator insulation quality assessment is an important issue for PWM inverter-fed machines, since the stator insulation is exposed to increased thermal/electrical stresses. In this paper, a new approach for monitoring the condition of the stator insulation for inverter-fed machines is proposed. The main concept of the proposed approach is to apply various types of test voltages to the motor stator insulation using the inverter, to perform standard off-line insulation tests whenever the motor is not operating. Two methods for testing the insulation with modifications to the inverter circuit are proposed and verified experimentally. The results show that the proposed technique provides a simple low cost solution for detecting stator insulation degradation at an early stage for reliable operation of inverter-fed machine systems, since the insulation condition can be monitored frequently. This not only helps prevent forced outages and safety risks due to insulation breakdown, but also helps perform maintenance in an efficient manner since individual motor maintenance can be prioritized and scheduled based on its present condition.
机译:定子绝缘质量评估是PWM逆变器馈电机的重要问题,因为定子绝缘暴露于增加的热/电应力。本文提出了一种用于监测用于逆变器供给机器的定子绝缘的状态的新方法。所提出的方法的主要概念是使用逆变器将各种类型的测试电压应用于电机定子绝缘,每当电动机未运行时都会执行标准离线绝缘测试。提出了两种测试绝缘的方法,并通过实验验证并验证了对逆变器电路的修改。结果表明,该技术提供了一种简单的低成本解决方案,用于检测定子绝缘降解在早期的逆变器供给机器系统的可靠操作,因为可以经常监测绝缘条件。这不仅有助于防止由于绝缘故障导致的强制停电和安全风险,而且还有助于以有效的方式进行维护,因为可以基于其现状优先考虑并安排各个电机维护。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号