This paper deals with a fundamental aspect in the control of grid-connected power converters, i.e., the detection of the positive-sequence component at fundamental frequency of the utility voltage under unbalanced and distorted conditions. Accurate and fast detection of this voltage component under grid faults is essential to keep the control over the power exchange with the grid avoiding to trip the converter protections and allowing the ride-through of the transient fault. In this paper, the systematic use of well known techniques conducts to a new positive-sequence voltage detection system which exhibits a fast, precise, and frequency-adaptive response under faulty grid conditions. Three fundamental functional blocks make up the proposed detector, these are: i) the quadrature-signals generator (QSG), ii) the positive-sequence calculator (PSC), and iii) the phase-locked loop (PLL). A key innovation of the proposed system is the use of a dual second order generalized integrator (DSOGI) to implement the QSG. For this reason, the proposed positive-sequence detector is called DSOGI-PLL. A detailed study of the DSOGI-PLL and verification by simulation are performed in this paper. From the obtained results, it can be concluded that the DSOGI-PLL is a very suitable technique for characterizing the positive-sequence voltage under grid faults.
机译:本文讨论了并网功率转换器的控制中的一个基本方面,即在不平衡和失真的情况下,在公用事业电压的基本频率下检测正序分量。在电网故障下准确,快速地检测该电压分量对于保持与电网的功率交换控制,避免使变流器保护跳闸并允许瞬态故障通过是至关重要的。在本文中,系统地使用众所周知的技术进行了一个新的正序电压检测系统,该系统在故障电网条件下表现出快速,精确和频率自适应的响应。所提出的检测器由三个基本功能块组成,它们是:i)正交信号发生器(QSG),ii)正序计算器(PSC),以及iii)锁相环(PLL)。拟议系统的关键创新是使用双二阶广义积分器(DSOGI)来实现QSG。因此,提出的正序检波器称为DSOGI-PLL。本文对DSOGI-PLL进行了详细的研究,并通过仿真进行了验证。从获得的结果可以得出结论,DSOGI-PLL是一种非常合适的技术,用于表征电网故障下的正序电压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号