摘要

Overloading and vibration compound test system which is combined by centrifuge and vibration table offers a new way for ground test to simulate flight. It is an important thing must be solved in the design of experiments for gyroscope under compound environment how to meet the requirement of linear acceleration and avoid influence of angle velocity of centrifuge. After analyzing the radius acceleration and confining condition of gyroscope in a centrifuge, a new design of combination plan is brought forward, which including regular octahedron six-point experiments, regular hexahedron eight-point experiments and round plane four-point experiments. The regression experiments of three factors two order quantic of gyroscope is realized by use of the centre combination design. It is shown in calculation that the new design of experiments reaches D-optimized criterion.
机译:离心机和振动台相结合的超载振动复合测试系统为地面飞行模拟飞行提供了一种新途径。如何满足线性加速度的要求,避免离心机角速度的影响,是复合环境下陀螺仪实验设计中必须解决的重要问题。在分析了离心机中陀螺仪的半径加速度和约束条件后,提出了一种新的组合方案设计方案,包括常规八面体六点实验,常规六面体八点实验和圆平面四点实验。利用中心组合设计实现了三因子二阶陀螺仪的回归实验。计算结果表明,新的实验设计达到了D优化的标准。

著录项