In this paper, a new technique for detecting inter turn short circuit fault in large turbogenerator rotor winding is presented. Based on single-end fault information, this new technique applies wavelet analysis method to inspect abruptly changed signals. The transient current traveling wave that generated in the rotor winding inter turn short circuit contains ample fault information, and its basic characteristic is current “abruptly changed”. According to the “abruptly changed”, there will be modulus maxima after wavelet transform, and we can detect generator inter turn short circuit fault through this characteristic. We have conducted correlative experiment on dynamic analog experiment unit, and the coincidence conclusion with the theory analyses is got.
机译:本文提出了一种检测大型汽轮发电机转子绕组匝间短路故障的新技术。该新技术基于单端故障信息,应用小波分析方法检查突然变化的信号。转子绕组匝间短路中产生的瞬变电流行波包含足够的故障信息,其基本特征是电流“突然改变”。根据“突变”,小波变换后会出现模数最大值,通过该特性可以检测出发电机匝间短路故障。我们在动态模拟实验单元上进行了相关实验,得出了与理论分析相吻合的结论。