We present an interpretation methodology for analysis of temperature profiles obtained in horizontal injectors with fiber optic distributed temperature sensors. We consider injection as a non-isothermal process, due to the contrast in the temperature of injected fluid and reservoir fluid. We examine the particular case of water injection in an oil-bearing reservoir and analyze a field case with a notable temperature contrast downhole (222 °F reservoir, 100 °F water). We examine the behavior of the wellbore temperature profile during injection, shut-in, and post-shut-in periods, for both short-term and long-term injection (days to months). We present a methodology for estimation of the injectivity profile along the length of the well during short-term injection, and discuss issues associated with interpretation of long-term data. The proposed methodology can be applied to injection testing of producing wells.
机译:我们提出了一种解释方法,用于分析在卧式喷油器中使用光纤分布式温度传感器获得的温度曲线。由于注入流体和储层流体温度的差异,我们将注入视为非等温过程。我们研究了含油储层注水的特殊情况,并分析了井下温度对比明显的现场案例(储层222°F,水100°F)。我们检查短期和长期注入(几天到几个月)在注入,关闭和关闭后井眼温度曲线的行为。我们提出了一种在短期注入过程中沿井眼长度对注入剖面进行估算的方法,并讨论了与长期数据解释相关的问题。所提出的方法可以应用于生产井的注入测试。