Worldwide, 30% - 40% of women and 13% of men suffer from osteoporotic fractures of the bone, particularly the older people. Doctors in the hospitals need to manually inspect a large number of x-ray images to identify the fracture cases. Automated detection of fractures in x-ray images can help to lower the workload of doctors by screening out the easy cases, leaving a small number of difficult cases and the second confirmation to the doctors to examine more closely. To our best knowledge, such a system does not exist as yet. This paper describes a method of measuring the neck-shaft angle of the femur, which is one of the main diagnostic rules that doctors use to determine whether a fracture is present at the femur. Experimental tests performed on test images confirm that the method is accurate in measuring neck-shaft angle and detecting certain types of femur fractures.
机译:在世界范围内,有30%-40%的女性和13%的男性患有骨质疏松性骨折,尤其是老年人。医院的医生需要手动检查大量的X射线图像以识别骨折病例。 X射线图像中骨折的自动检测可以通过筛选出易患病例,留下少量疑难病例以及第二次确认让医生进行更仔细的检查来帮助减轻医生的工作量。据我们所知,这样的系统尚不存在。本文介绍了一种测量股骨颈轴角度的方法,这是医生用来确定股骨是否存在骨折的主要诊断规则之一。在测试图像上进行的实验测试证实,该方法在测量颈轴角度和检测某些类型的股骨骨折方面是准确的。