首页> 外文会议>Seventeenth European Photovoltaic Solar Energy Conference >PVSAT: Remote Performance Check for Grid Connected PV Systems Using Satellite Data, Evaluation of one Year of Field-Testing
【24h】

PVSAT: Remote Performance Check for Grid Connected PV Systems Using Satellite Data, Evaluation of one Year of Field-Testing

机译:PVSAT:使用卫星数据的并网光伏系统的远程性能检查,评估一年的现场测试

获取原文

摘要

The PVSAT procedure provides users of grid-connected PV systems with an individual monthly reference yield. Comparison of this reference yield with measured yield can identify system faults. This paper describes the one-year field test of the PVSAT procedure. The field test was used to test and improve the PVSAT software and organisation; to determine the differences between measured and reference yield under field conditions; to establish the causes of these differences and to determine when a system operator or system supplier should be warned about a possible malfunction within in the system. During the one-year test phase 69 owners of PV-systems in Austria, Germany, the Netherlands and Switzerland reported their measured monthly yield and received a reference yield. The field test enabled us to identify and solve problems in the procedure. Throughout the year the normalised difference between measured and reference yield remained within a band throughout the year, but some outliers occur. An analysis of the data showed that the differences between measured and reference yields could be partially explained by system faults, nearby shading, inaccurate horizon description, inaccurate specifications of components and insufficient accuracy of the PVSAT irradiation model (during one or two months in the year). The results were, where possible, corrected for external effects. This gave a first estimate of the accuracy of the PVSAT procedure under field conditions of 15 to 20 kWh/kWp. This accuracy can be improved if the system installer describes the PV system and surroundings, the true peak power of modules is included in module specifications and a model for the shading of nearby objects is included in the PVSAT model.
机译:PVSAT程序为并网光伏系统的用户提供单独的每月参考收益。将该参考产量与测得的产量进行比较可以识别系统故障。本文介绍了PVSAT程序的一年现场测试。现场测试用于测试和改进PVSAT软件和组织。确定田间条件下测得的产量与参考产量之间的差异;确定造成这些差异的原因,并确定何时应警告系统操作员或系统供应商系统内部可能存在的故障。在一年的测试阶段中,奥地利,德国,荷兰和瑞士的69个光伏系统所有者报告了他们测得的每月收益并获得了参考收益。现场测试使我们能够识别并解决程序中的问题。全年中,测得的收益率和参考收益率之间的标准化差值全年都保持在一个范围内,但是会出现一些离群值。对数据的分析表明,所测得的收益率与参考收益率之间的差异可以部分归因于系统故障,附近的阴影,不正确的水平线描述,不正确的组件规格以及PVSAT辐射模型的准确性不足(一年或两个月内) )。在可能的情况下,将结果校正为外部影响。这给出了在15至20 kWh / kWp的现场条件下PVSAT程序准确性的初步估计。如果系统安装人员描述了光伏系统及其周围环境,模块的真正峰值功率包含在模块规格中,并且用于附近物体遮蔽的模型包含在PVSAT模型中,则可以提高此准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号