摘要

The 68 kWp PV system was installed on shading canopies in a parking area at the University of Jaen and forms part of the UNIVER Project funded under the European Commission's THERMIE Demonstration Programme. The analysis presented in this paper covers the period of operation between November 1999, shortly after system installation, to October 2000. The paper describes the determination of typical performance levels during normal operation, the investigation of the system losses and prediction of annual output and yield values. Close agreement was obtained between predicted and measured performance ratios. The average annual system efficiency was determined to be 8.1%, with an average performance ratio of 65.4%, for periods of full operation. The measured annual yield for the system was 833 kWh/kWp. However, using the calculated data, an annual yield of 1170 kWh/kWp is predicted in the absence of any operational problems.
机译:68 kWp的光伏系统安装在哈恩大学停车场的遮阳棚上,并且是由欧盟委员会THERMIE示范计划资助的UNIVER项目的一部分。本文提供的分析涵盖了系统安装后从1999年11月到2000年10月的运行时间。该文件描述了正常运行期间典型性能水平的确定,系统损耗的调查以及年产量和产量的预测价值观。在预测和测量的性能比率之间获得了紧密的一致性。在完全运行期间,确定的年平均系统效率为8.1%,平均性能比率为65.4%。该系统测得的年发电量为833 kWh / kWp。但是,使用计算得出的数据,在没有任何操作问题的情况下,预计年发电量将达到1170 kWh / kWp。