The use of cavity pressure for velocity to pressure transfer during the injection phase of the molding process is generally considered to be the most repeatable method. This study looked at the effect of cavity pressure transducer location and the velocity at which transfer occurs for three different process strategies: 1) transfer before the melt front hits the last place to fill, 2) transfer during the pack phase with the screw going relatively fast, and 3) transfer at the end of pack with the screw going relatively slow. This experiment found that, as long as an inflection point is seen in the cavity pressure curve, it does not matter which cavity pressure transducer location is used when considering process consistency.
机译:通常认为在模制过程的注射阶段使用型腔压力来实现速度到压力的传递是最可重复的方法。这项研究研究了三种不同工艺策略下模腔压力传感器位置和转移速度的影响:1)在熔体前沿到达最后一个填充位置之前转移; 2)在组装阶段转移,同时螺杆相对移动快速); 3)在包装末端转移时,螺丝相对较慢。该实验发现,只要在型腔压力曲线中看到拐点,在考虑工艺一致性时,使用哪个型腔压力传感器位置都无关紧要。