Experimental investigation on sliding and fretting wear of steam generator tube materials

机译:蒸汽发生器管材滑动和微动磨损的实验研究

获取原文
获取外文期刊封面目录资料

摘要

In nuclear power steam generators, high flow rates can induce vibration of the tubes resulting in fretting wear damage due to contacts between the tubes and their supports. In this paper, the sliding and fretting wear tests were performed using Inconel 600HTMA and 690TT against STS 304, which are the steam generator tube materials. The sliding wear tests with a pin-on-disk type tribometer were carried out under various applied loads and sliding speeds at air environment. The fretting wear tests were carried out under various vibrating amplitudes and applied normal loads. The result of sliding and fretting wear tests show that the heat-treated Inconel 690TT has better wear resistance than Inconel 600HTMA in air. The fretting wear regimes were plotted using the test results and the wear coefficient was calculated also. From the results, it was observed that the wear and tear by stick-slip has very strong effect on the fretting wear behavior.
机译:在核动力蒸汽发生器中,高流速会引起管子的振动,从而由于管子及其支撑件之间的接触而导致微动磨损损坏。在本文中,使用Inconel 600HTMA和690TT对蒸汽发生器管材料STS 304进行了滑动和微动磨损测试。在空气环境下,在各种施加的载荷和滑动速度下,使用销盘式摩擦计进行了滑动磨损测试。微动磨损试验是在各种振动幅度和施加正常载荷的条件下进行的。滑动和微动磨损测试的结果表明,经过热处理的Inconel 690TT在空气中具有比Inconel 600HTMA更好的耐磨性。使用测试结果绘制了微动磨损状态,并计算了磨损系数。从结果可以看出,粘滑引起的磨损对微动磨损行为有很强的影响。