The results presented here are examples and show the trend of the results of a more extensive investigation. It has been shown that the arrangement of the six-coil system carrying typical currents does not induce sufficient flux density distribution, at the surface of the part, to provide valid magnetic particle inspection, when compared with the traditional single coil system. The advantage of the single coil system is that the part may be placed in the center of the coil while the part lies between two coils in the six coil apparatus.
机译:此处提供的结果是示例,显示了更广泛调查结果的趋势。已经表明,与传统的单线圈系统相比,载有典型电流的六线圈系统的布置不会在零件表面感应出足够的磁通密度分布,从而无法提供有效的磁粉检查。单线圈系统的优点在于,该部件可以放置在线圈的中心,而该部件位于六个线圈装置中的两个线圈之间。