We studied experimentally the impact of 600 micron diameter molten tin droplets on a stainless steel surface. We varied the impact velocity (10-40 m/s) and photographed impacting droplets. A molten tin droplet generator was used to produce molten tin droplets. The stainless steel substrate was mounted on the end of a rotating arm, which gave linear velocities of up to 40m/s. A CCD camera was used to photograph droplets impinging on the substrate. By synchronizing the ejection of a single droplet with the position of the arm and triggering of the camera, different stages of droplet impact were photographed. From these photographs we measured the maximum diameter to which droplet spread and recorded the velocity at which splashing was first observed. At high impact velocities (above 20 m/s) and for substrates at room temperature we did not observe formation of distinct fingers around the periphery of the drop. Instead, fragments of molten metal detached from the edge of spreading rim. We also observed that the central portion of the splat detached from the spreading rim and separated from the substrate after impact.
机译:我们通过实验研究了直径为600微米的熔融锡滴对不锈钢表面的影响。我们改变了撞击速度(10-40 m / s)并拍摄了撞击液滴。熔融锡滴发生器用于产生熔融锡滴。将不锈钢基板安装在旋转臂的末端,旋转臂的线速度高达40m / s。使用CCD相机拍摄撞击在基板上的液滴。通过将单个液滴的喷射与手臂的位置同步并触发相机,可以对液滴撞击的不同阶段进行拍照。从这些照片中,我们测量了液滴散布的最大直径,并记录了首次观察到飞溅的速度。在高冲击速度(高于20 m / s)下以及对于室温下的基材,我们没有观察到液滴周围形成明显的指状物。取而代之的是,熔融金属碎片从铺展轮辋的边缘脱落。我们还观察到,撞击后,splat的中心部分从扩展边缘分离并与基底分离。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号