首页> 外文会议>International conference on electrical machines and systems;ICEMS'2001 >Comparison of Performance Analysis of Synchronous Generators with Simultaneous AC and DC Stator Connections Using Multi-loop Model and Multi-loop FEM Model
【24h】

Comparison of Performance Analysis of Synchronous Generators with Simultaneous AC and DC Stator Connections Using Multi-loop Model and Multi-loop FEM Model

机译:交流发电机和直流发电机同时连接的同步发电机性能的多回路模型和多回路有限元模型比较

获取原文

摘要

In order to find out an accurate and efficient way to predict the performance of synchronous generators with simultaneous AC and DC stator connections, two different models, multi-loop model and multi-loop FEM model, are described in this paper. As comparison and verification, the calculated results by these two models are compared with those of experiments. The multi-loop FEM model is more accurate than the multi-loop model under various conditions, but it is more time-consuming.
机译:为了找到一种准确有效的方法来预测同时具有交流和直流定子连接的同步发电机的性能,本文描述了两种不同的模型,即多回路模型和多回路有限元模型。作为比较和验证,将这两个模型的计算结果与实验结果进行比较。在各种条件下,多环FEM模型比多环模型更准确,但更耗时。