首页> 外文会议>Waterpower conference >Intake Current-Meter Calibration Program And Results
【24h】

Intake Current-Meter Calibration Program And Results

机译:进气电流表校准程序和结果

获取原文

摘要

St. Lawrence Plant has 32 units installed on an international dam that extends betweenU.S.A and Canada. The units operate under low head between 22 to 27 m. The unitconfiguration does not fit any testing methodology except the velocity area methodusing the Current-Meters in the unit intake. Turbine performance testing for the St.Lawrence plant was carried out by the Velocity Area Method using the Intake CurrentMeters.A calibration program was developed to determine the effect of the current-metersupportingframe on the flow measurement to ensure the flow measurement accuracy.The calibration program was designed to determine the effect of the frame blockage onthe flow measurement and the effect of the supporting frame proximity on the flowmeasurement. The calibration program also studied the effect of meter proximity toother meters in the horizontal and vertical positions and meter proximity to the walls andthe effect of oblique flow.This presentation will describe the calibration program, the results and the conclusionsfrom that calibration program.
机译:圣劳伦斯工厂在国际大坝上安装了32个单元,该大坝之间 美国和加拿大。这些装置在22至27 m的低水头下运行。那个单位 除速度区域方法外,该配置不适合任何测试方法 在单位进气口使用电流表。涡轮性能测试 劳伦斯工厂是采用进气面积通过速度面积法进行的 米。 开发了一个校准程序来确定电流表支持的效果 流量测量上的框架,以确保流量测量的准确性。 校准程序旨在确定帧阻塞对 流量测量以及支撑架接近度对流量的影响 测量。校准程序还研究了电表接近 其他仪表在水平和垂直位置,以及仪表与墙壁的接近程度,以及 斜流的影响。 本演讲将描述校准程序,结果和结论 从该校准程序。