The calculations of noise equivalent temperature difference (NETD) for thermovision devices are carried out, with cut-off wavelengths of photo detectors (lambda_co) and distance to target used as parameters. For the estimation of influence of the photodiode spectral characteristics on the parameters of thermovision systems several characteristics were taken into account: the spectrum of radiation of object, transmission of an atmosphere and spectral characteristic of sensitivity of photo-diode array. The results show that an increase of lambda_co above 10,5 microns at small distances improves the temperature resolution not more than 15
机译:进行了热成像设备的噪声等效温差(NETD)的计算,其中光电检测器的截止波长(lambda_co)和到目标的距离用作参数。为了估计光电二极管光谱特性对热像仪系统参数的影响,考虑了几个特性:物体的辐射光谱,大气透射率和光电二极管阵列的灵敏度光谱特性。结果表明,小距离处,lambda_co的增加超过10.5微米,则温度分辨率提高到不超过15微米