based on the analysis of normal load breaking's peculiarity, the dynamic interrupting characteristic and dielectric recovery characteristic of high voltage SF_6 puffer breaker are simulated during breaking normal load current. Result indicates that there exist more surpluses on interrupting capacity when breaking rated current. Employing the method of simulating the arcing time window, combined with the circuit breaker "Intelligent Operation" theory, the necessary minimum opening velocity is obtained.
机译:在分析正常负载分断特性的基础上,模拟了高压SF_6吹气断路器在分断正常负载电流时的动态中断特性和介电恢复特性。结果表明,在断开额定电流时,中断能力会有更多的剩余。采用模拟电弧时间窗口的方法,结合断路器的“智能操作”理论,获得了必要的最小断开速度。