首页> 外文会议>International conference on biofilm systems >Suspended carrier technology allows upgrading high-rate activated sludge plants for nitrogen removal via process intensification
【24h】

Suspended carrier technology allows upgrading high-rate activated sludge plants for nitrogen removal via process intensification

机译:悬浮载体技术可以升级高速率活性污泥装置,以通过工艺强化来去除氮

获取原文

摘要

The Oxley Creek wastewater treatment plant is a conventional 185,000 EP BOD removal activated sludge plant that is to be upgraded for nitrogen removal to protect its receiving water bodies, the Brisbane River and Moreton Bay. Suspended carrier technology is one possible way of upgrading this activated sludge wastewater treatment plant for nitrogen removal. Freely moving plastic media is added to the aeration zone, providing a growth platform for nitrifying bacteria and increasing the effective solids residence time (SRT). This paper presents the results from operating a pilot plant for 7 months at the Oxley Creek WWTP in Brisbane, Australia. Natrix Major 12/12 plastic media, developed by ANOX (Lund, Sweden), was trialed in the pilot plant. The pilot plant was operated with a mixed liquor suspended solids concentration of 1220 mg/L and a total hydraulic residence time of 5.4 hours, similar to the operating conditions in the full-scale Stage 1&2 works at the Oxley Creek WWTP. The plastic carriers were suspended in the last third of the bioreactor volume, which was aerated to a DO setpoint of 4.0 mg/L. The first third of the bioreactor volume was made anoxic and the second third served for carbon removal, being aerated to a DO setpoint of 0.5 mg/L. The results from the pilot plant indicate that an average effluent total inorganic nitrogen concentration (ammonia-N plus NO_x-N) of less than 12 mg/L is possible. However, the effluent ammonia concentrations from the pilot plant showed large weekly fluctuations due to the intermittent operation of the sludge dewatering centrifuge returning significant ammonia loads to the plant on three days of the week. Optimising denitrification was carried out by lowering the DO concentration in the influent and in the carbon removal reactor. The results from the pilot plant study show that the Oxley Creek WWTP could be upgraded for nitrogen removal without additional tankage, using suspended carrier technology.
机译:Oxley Creek废水处理厂是常规的185,000 EP BOD去除活性污泥厂,将对其进行升级以去除氮,以保护其接收水体,布里斯班河和Moreton Bay。悬浮载体技术是升级此活性污泥废水处理厂以去除氮的一种可能方法。自由运动的塑料介质被添加到曝气区,为硝化细菌提供了一个生长平台,并增加了有效固体停留时间(SRT)。本文介绍了在澳大利亚布里斯班的Oxley Creek污水处理厂运营中试工厂七个月的结果。由ANOX(瑞典隆德)开发的Natrix Major 12/12塑料介质在中试工厂中进行了试验。与混合液悬浮固体浓度为1220 mg / L,总水力停留时间为5.4小时的中试工厂一起运行,与Oxley Creek WWTP的第一和第二阶段全面工程的运行条件相似。将塑料载体悬浮在生物反应器体积的最后三分之一中,将其充气至DO设定值4.0 mg / L。将生物反应器体积的前三分之一设为缺氧,后三分之一用于除碳,充气至DO设定值为0.5 mg / L。中试厂的结果表明,平均出水总无机氮浓度(氨氮+ NO_x-N)小于12 mg / L是可能的。但是,由于污泥脱水离心机的间歇性运行,使得中试工厂的出水氨浓度每周出现较大波动,这在一周的三天中将大量的氨负荷返还给了工厂。通过降低进水口和除碳反应器中的溶解氧浓度来优化反硝化作用。中试工厂研究的结果表明,使用悬浮载体技术,可以将Oxley Creek污水处理厂升级为脱氮设备,而无需额外的储罐。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号