This paper provides a summary of the methodology and the results of a Probabilistic Safety Assessment (PSA) work for a severe seismic event that was performed in support the Design Certification of the ABB Combustion Engineering System 80+~(TM) Standard Plant Design. The adopted mehtod uses a technique called PSA-Based Seismic Margin Assessment (PSA-SMA). The PSA-SMA was performed to assess the ability of the System 80+standard design in response to a seismic event beyond the Design Basis Earthquake (DBE). The design-basis earthquake for System 80+ is defined as an earthquake having a 0.3g Peak Ground Acceleration (PGA). The seismic margin assessment was conducted with respect to a Review Level Earthquake (RLE) having a Peak Ground Acceleration of 0.6g. The resistance of the design to severe earthquakes was then demonstrated to be greater than the RLE.
机译:本文概述了为支持ABB燃烧工程系统80 +〜TM标准工厂设计的设计认证而进行的严重地震事件的方法学和概率安全评估(PSA)工作的结果。所采用的方法采用了一种称为基于PSA的地震裕度评估(PSA-SMA)的技术。进行PSA-SMA评估系统80 +标准设计的能力,以应对超出设计基准地震(DBE)的地震事件。系统80+的设计基准地震定义为具有0.3g峰值地面加速度(PGA)的地震。地震余量评估是针对地面加速度峰值为0.6g的“回顾级地震”(RLE)进行的。然后证明了该设计对强震的抵抗力大于RLE。