首页> 外文会议>International workshop on structural health monitoring >Composite Structures Integrity Monitoring Using Rotating Electrical Signals
【24h】

Composite Structures Integrity Monitoring Using Rotating Electrical Signals

机译:复合结构完整性监控使用旋转电信号

获取原文

摘要

Composite Electrical impedance to evaluate composite damage is receiving growing attention from the research community as an alternative approach to ultrasounds and other non-destructive techniques. It is still in development, but recent years steady technologies advanced have increased understanding and process capability, in fact in literature there are even reports of damage detection using impedance missed by other technologies. Ultrasounds technology is very mature and robust and remain elite technique but when it comes to access recesses and complex geometries further advantages could be achieved if a smaller and relatively simpler monitoring equipment could be available. Objective of this poster is lay preliminary research to evaluate the possibility of simplifying impedance analyses using multiple circularly arranged sensors that can be interrogated with specific sequences and interpreting algorithms.
机译:复合电气阻抗评估综合损伤正在从研究界产生越来越关注,作为超声波和其他非破坏性技术的替代方法。它仍在开发中,但近年来稳定的技术先进的理解和过程能力提高,实际上在文献中,甚至还有损坏的报告,使用其他技术错过了阻抗。超声波技术是非常成熟和坚固的,并且保持精英技术,但是当涉及到访问凹槽时,如果可以使用较小且相对更简单的监视设备,可以实现复杂的几何形状。该海报的目的是初步研究,以评估使用可以用特定序列和解释算法询问的多个圆形布置的传感器来简化阻抗分析的可能性。