The anticipated performance of a 4-story reinforced concrete (RC) building designed in accordance with ASCE/SEI 7, is assessed using ASCE/SEI 41. Engineering practitioners employing the performance-based seismic engineering philosophy are increasingly using ASCE/SEI 41, as the "first generation" performance-based seismic design principle, to justify the adequacy of the seismic performance of new buildings. However, ASCE/SEI 41 was developed to assess the structural performance of existing buildings. In order to compare the anticipated structural performance between ASCE 7 and ASCE 41, the seismic performance of an ASCE/SEI 7 code-compliant 4-story special RC moment frame building is assessed based on the four evaluation methodologies defined in the Tier 3 analysis of ASCE/SEI 41 for the collapse prevention structural performance level. The assessment results show that the ASCE/SEI 7 code-compliant building does not meet the collapse prevention performance level requirements in ASCE/SEI 41 for the columns in the first story when linear analyses are employed.
机译:使用ASCE / SEI 41评估了根据ASCE / SEI 7设计的4层钢筋混凝土(RC)建筑的预期性能。使用基于绩效的地震工程哲学的工程从业者越来越多地使用ASCE / SEI 41,如“第一代”绩效的争论地震设计原则,以证明新建筑的地震性能的充分性。但是,开发了ASCE / SEI 41以评估现有建筑物的结构性。为了比较ASCE 7和ASCE 41之间的预期结构性能,根据第3层分析中定义的四种评估方法进行评估ASCE / SEI 7代码符合的4层特殊RC矩框架建筑的地震性能ASCE / SEI 41用于崩溃的结构性能水平。评估结果表明,当采用线性分析时,符合ASCE / SEI 7代码符合符合符合ASCE / SEI 41中的崩溃预防性能水平要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号