首页> 外文会议>International conference on magnet technology;MT-15 >Design, Fabrication and Testing of a 100 kA Superconducting Transformer for the SULTAN Test Facility
【24h】

Design, Fabrication and Testing of a 100 kA Superconducting Transformer for the SULTAN Test Facility

机译:用于SULTAN测试设施的100 kA超导变压器的设计,制造和测试

获取原文

摘要

To meet the specifications of ITER candidate conductors, the SULTAN Test Facility has been upgraded with a new superconducting transformer which allows ratings of the test samples up to 100kA under different cooling conditions. The transformer consists of two concentric layer-wound superconducting solenoids with the primary inside the secondary. The 100 kA secondary conductor is a rectangular cable-in-conduit type based on NbTi superconductor. The process that led to the selection of this conductor and some of the consequences of the choice for fabrication and operation are presented. The design principles of the transformer and the manufacturing techniques are discussed. Operational results carried out on an ITER prototype conductor are also presented.
机译:为了满足ITER候选导体的规格,SULTAN测试设备已升级为新的超导变压器,该变压器可以在不同的冷却条件下对高达100kA的测试样品进行额定工作。变压器由两个同心绕制的超导螺线管组成,初级线圈位于次级线圈内。 100 kA次级导体是基于NbTi超导体的矩形电缆导管型。介绍了导致选择该导体的过程以及选择制造和操作的一些后果。讨论了变压器的设计原理和制造技术。还介绍了在ITER原型导体上执行的操作结果。