The mechanical and optical properties of the metallized Teflon~direct R FEP thermal control materials on the Hubble Space Telescope (HST) have degraded over the nearly seven years the telescope has been in orbit. Given the damage to the outer layer of the multi-layer insulation (MLI) that was apparent during the second servicing mission (SM2), the decision was made to replace the outer layer during subsequent servicing missions. A Failure Review Board was established to investigate the damage to the MLI and identify a replacement material. The replacement material had to meet the stringent thermal requirements of the spacecraft and maintain structural integrity for at least ten years.
机译:哈勃太空望远镜(HST)上的金属化特氟龙直接R FEP热控制材料的机械和光学性能在望远镜进入轨道的近七年中已经退化。鉴于在第二次维修任务(SM2)期间对多层绝缘材料(MLI)的外层造成了明显损坏,因此决定在随后的维修任务中更换外层。成立了故障审查委员会,以调查对MLI的损坏并确定替换材料。替代材料必须满足航天器的严格热学要求,并至少保持十年的结构完整性。