COMPARISON OF TEST METHODS FOR HEARING PROTECTOR ATTENUATION MEASUREMENTS

机译:听力保护器衰减测试方法的比较

获取原文

摘要

Based on the data presented here the variation caused by the realisation of the sound field is of the same order of magnitude as the variation caused by the different test subjects. Especially for plugs, where the standard deviations are great, even clear differences in the mean attenuation values will turn out to be non- significant and therefore the specific realisation of the sound field may be of minor importance. The lack of subjects fitting experience leads to less attenuation for plugs (figure 3) but almost the same attenuation for muffs. A comparison test coordinated by BIA, Sankt Augustin, Germany, between European test laboratories was finalised at the end of 1997. The results are presented elsewhere. Hence, much information is available for the ongoing revision of the ISO 4869-1 standard.
机译:根据此处提供的数据,由声场实现引起的变化与由不同测试对象引起的变化具有相同的数量级。特别是对于标准偏差较大的插头,即使平均衰减值的明显差异也将变得无关紧要,因此声场的具体实现可能次要。缺乏受试者的装配经验会导致塞子的衰减较小(图3),而罩子的衰减几乎相同。由BIA(位于德国圣奥古斯丁)与欧洲测试实验室之间进行的比较测试于1997年底完成。结果在其他地方介绍。因此,有大量信息可用于正在进行的ISO 4869-1标准的修订。