This paper covers the design and initial performance analysis of the radiometric calibration pipeline software for the EO-1 Advanced Land Imager (EO-1). The design and implementation of the software and of the radiometric calibration database are discussed. Radiometric calibration data were gathered in the laboratory during integration and test and were used for initializing the database. This database will be updated in the future with data collected on orbit. Initial performance results have been obtained after applying the radiometric calibration to imaging data collected during ALI integration and test and ground calibration. During the initial test it was noted a few detectors leaked energy into other detectors, thereby requiring special calibration processing for the affected detectors. The handling of this anomaly is discussed, and the initial performance results of the calibration pipeline with the anomaly corrections will be shown.
机译:本文涵盖了EO-1高级陆地成像器(EO-1)的辐射校准管道软件的设计和初始性能分析。讨论了软件和辐射校准数据库的设计和实现。在集成和测试期间在实验室中收集了辐射校准数据,并用于初始化数据库。此数据库将在将来更新,并使用轨道上收集的数据进行更新。在将辐射校准应用于ALI集成和测试和地面校准期间收集的成像数据之后获得了初始性能结果。在初始测试期间,注意到一些探测器将能量泄漏到其他探测器中,从而需要对受影响的探测器进行特殊校准处理。讨论了这种异常的处理,并显示了具有异常校正的校准管道的初始性能结果。

著录项