Cyclic lateral-loading centrifuge tests were performed on a model of an embedded foundation using the 100 g-ton RPI centrifuge facility. The purpose of these tests was to study the lateral response of the embedded footing at various displacementlevels up to failure. A reinforced concrete footing has been modeled with prototype dimensions of 1.14×1.14×0.84 m (1×w×h). Dry Nevada sand of 75 % relative density was used. The results are relevant to shallow foundations and embedded pile caps. Thetests' objective was to evaluate the relative contributions to total lateral response of the base, shearing sides, and active/passive sides of the foundation, as well as any possible interaction between these partial contributions. Lateral responseparameters studied included secant stiffness and material damping ratio at various displacement amplitudes, and ultimate lateral capacity.
机译:使用100 G-TON RPI离心机设施对嵌入式基础的模型进行循环横向加载离心机试验。这些测试的目的是研究嵌入的脚踏的侧向响应,以达到失败的各种位移。钢筋混凝土基础已经采用1.14×1.14×0.84米(1×W×H)的原型尺寸。使用75%相对密度的干燥内华达沙子。结果与浅层基础和嵌入式桩帽有关。最近的目的是评估基础,剪切侧和主动/被动侧的基础,剪切面和主动/被动侧的相对贡献,以及这些部分贡献之间的任何可能的相互作用。所研究的横向响应分数包括在各种位移幅度的割升刚度和材料阻尼比,以及最终的横向容量。