首页> 外文会议> >An automated real time microscopy system for analysis of Fluorescence Resonance Energy Transfer
【24h】

An automated real time microscopy system for analysis of Fluorescence Resonance Energy Transfer

机译:自动化实时显微镜系统,用于分析荧光共振能量转移

获取原文
获取原文并翻译 | 示例

摘要

Molecular imaging based on Fluorescence Resonance Energy Transfer (FRET) is widely used in cellular physiology both for protein-protein interaction analysis and detecting conformational changes of single proteins, e.g. during activation of signaling cascades. However, getting reliable results from FRET measurements is still hampered by methodological problems such as spectral bleed through, chromatic aberration, focal plane shifts and false positive FRET. Particularly false positive FRET signals caused by random interaction of the fluorescent dyes can easily lead to misinterpretation of the data. This work introduces a Nipkow Disc based FRET microscopy system, that is easy to operate without expert knowledge of FRET. The system automatically accounts for all relevant sources of errors and provides various result presentations of two, three and four dimensional FRET data. Two examples are given to demonstrate the scope of application. An interaction analysis of the two subunits of the hypoxia-inducible transcription factor 1 demonstrates the use of the system as a tool for protein-protein interaction analysis. As an example for time lapse observations, the conformational change of the fluorophore labeled heat shock protein 33 in the presence of oxidant stress is shown.
机译:基于荧光共振能量转移(FRET)的分子成像技术在细胞生理学中广泛用于蛋白质-蛋白质相互作用分析和检测单个蛋白质的构象变化,例如在激活信号级联期间。但是,仍然无法通过方法问题(例如光谱渗漏,色差,焦平面偏移和假正FRET)阻碍FRET测量获得可靠的结果。特别是由荧光染料的随机相互作用引起的假阳性FRET信号很容易导致数据误解。这项工作介绍了一个基于Nipkow光盘的FRET显微镜系统,该系统在没有FRET专业知识的情况下易于操作。该系统自动解决所有相关的错误源,并提供二维,三维和四维FRET数据的各种结果表示。给出两个例子来说明应用范围。对低氧诱导型转录因子1的两个亚基的相互作用分析证明了该系统作为蛋白质-蛋白质相互作用分析工具的用途。作为时间推移观察的示例,示出了在存在氧化应激的情况下荧光团标记的热激蛋白33的构象变化。

著录项

  • 来源
    《》|2010年|P.772311.1-772311.8|共8页
  • 会议地点 Brussels(BE)
  • 作者单位

    Institute of Physiology, University of Duisburg-Essen, Hufelandstr. 55, 45122 Essen, Germany Biomedical Imaging Group, University of Applied Sciences and Arts Dortmund, Emil-Figge-Str. 42, 44227 Dortmund, Germany;

    rnInstitute of Physiology, University of Duisburg-Essen, Hufelandstr. 55, 45122 Essen, Germany;

    rnBiomedical Imaging Group, University of Applied Sciences and Arts Dortmund, Emil-Figge-Str. 42, 44227 Dortmund, Germany;

    rnInstitute of Physiology, University of Duisburg-Essen, Hufelandstr. 55, 45122 Essen, Germany;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 多媒体技术与多媒体计算机;应用光学;
  • 关键词

    FRET; microscopy; confocal; real time; sensitized emission;

    机译:烦恼;显微镜共焦即时的;敏化发射;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号