首页> 外文会议>International conference on coal science;ICCS '97 >Mathematical model of spontaneous heating of activated coke filters
【24h】

Mathematical model of spontaneous heating of activated coke filters

机译:活性炭过滤器自发加热的数学模型

获取原文

摘要

Activated brown coal coke for flue gas clean-up reacts with the oxygen contained in the flue gas under operating conditions. The oxidation heat released increases the filter bed temperature, which in case of heat accumulation may even induce spontaneous ignition of the activated coke fill. The newly developed mathematical model of the self-heating process taking place in a moving bed filter allows predicting the time-related courses of temperature and O_2-concentration along the filter axis, also if gas velocity is extremely low.
机译:在操作条件下,用于烟道气净化的活性褐煤焦炭会与烟道气中所含的氧气发生反应。释放出的氧化热增加了滤床的温度,在积聚热量的情况下,甚至可能引起活性焦炭填充物的自燃。在气体床速度极低的情况下,在移动床过滤器中进行的新开发的自加热过程数学模型还可以预测沿时间和温度相关的过程以及沿过滤器轴的O_2浓度。