首页> 外文会议>World conference on NDT;14th WCNDT >Ultrasonic Technique for Quantitative Evaluation of Dispersed Particles in Metal Matrix Composite
【24h】

Ultrasonic Technique for Quantitative Evaluation of Dispersed Particles in Metal Matrix Composite

机译:超声技术定量评价金属基复合材料中分散颗粒

获取原文

摘要

In this paper, we present a new method of ultrasonic Inspection for nondestructive characterization of metal matrix composite. From the results of ultrasonic tests of Al/SiCp composite, the following important raws of ultrasonic waves were revealed. (1) Propagation time decreases with an increase in SiCp volume fraction; and (2) pulse width increases with an increase in SiCp size. We studied these phenomena based on a probabilistic method, and derived formulas for the relationship between ultrasonic waves (propagation time and pulse width) and dispersed aprticles (volume fraction and mean size).
机译:在本文中,我们提出了一种用于金属基复合材料无损表征的超声检查新方法。从Al / SiCp复合材料的超声测试结果来看,发现了以下重要的超声波原料。 (1)传播时间随着SiCp体积分数的增加而减少; (2)脉冲宽度随着SiCp尺寸的增加而增加。我们基于概率方法研究了这些现象,并推导了超声波(传播时间和脉冲宽度)与分散心室(体积分数和平均大小)之间关系的公式。