Micromagnetic Barkaussen emissions technique is used to determine the surface stress-state of shot peened suspension spring which failed while in service. Different surface stress states alogn the circumference of the spring are observed which are confirmed by XRD. The presence of high tensile stress at the subsurface is also indicated by XRD. Different surface stress occurrence of high tensile stress at the subsurface and presence of high inclusion ratings in the material are found to be the cause of failure of spring.
机译:微电磁Barkaussen发射技术用于确定喷丸硬化弹簧在使用中失败的表面应力状态。观察到弹簧圆周周围的不同表面应力状态,这已通过XRD确认。 XRD也表明在地下存在高拉伸应力。发现在表面下出现不同的表面应力,产生高的拉伸应力以及材料中存在高的夹杂物等级是弹簧失效的原因。