Passive autocatalytic recombiners for mitigating containment hydrogen concentrations following design basis accidents in nuclear power plants

机译:被动式自催化重组器,用于缓解核电站设计基准事故后的安全壳氢浓度

获取原文
获取外文期刊封面目录资料

摘要

Passive autocatalytic recombiners (PARs) offer a simple and dependable method for limiting hydrogen concentrations in PWR containments (or oxygen concentrations in inerted BWRs) under design basis accident conditions. Empirical and theoretical models for predicting PAR performance are described. Calculations based on these models agree well with test data for both full-size units and small-scale modules. Calculations for a design basis accident scenario in an operating PWR indicate that one PAR would be sufficient to limit containment hydrogen concentration to well below the 4
机译:被动式自动催化重组器(PAR)提供了一种简单可靠的方法来限制设计基准事故情况下PWR容器中的氢浓度(或惰性BWR中的氧浓度)。描述了用于预测PAR性能的经验和理论模型。基于这些模型的计算与全尺寸单元和小型模块的测试数据非常吻合。对运行中的压水堆中设计基准事故情景的计算表明,一个PAR将足以将安全壳氢浓度限制在远低于4的水平。