首页> 外文会议>International topical meeting on nuclear thermal hydraulics, operations and safety;NUTHOS-5 >Failure analysis of globe control valves with spring-diaphragm actuator for nuclear power plant applications
【24h】

Failure analysis of globe control valves with spring-diaphragm actuator for nuclear power plant applications

机译:带有弹簧膜片执行器的截止阀的故障分析,用于核电站

获取原文

摘要

The results of the failure analysis of a globe control valve with spring-diaphragm actuator indicated that the diaphragm failed because the service loading is close to the strength of the diaphragm. The resulting impact force is significantly larger than the plug guide strength and that cause it to bulge out after the impact. To improve the valve performance, proper torque should be used to tighten the actuator diaphragm case fasteners. A stronger actuator diaphragm could be used to provide additional safety margin during operation. Stiffening the plug guide may avoid jamming the bushing.
机译:对带有弹簧-膜片执行器的截止阀的故障分析结果表明,膜片发生故障,因为使用载荷接近膜片的强度。产生的冲击力显着大于插塞导向器的强度,导致其在冲击后鼓出。为了提高阀门性能,应使用适当的扭矩来拧紧执行器膜片盒紧固件。在操作期间,可以使用更坚固的执行器隔膜来提供额外的安全余量。加强插头导向器可避免卡住衬套。