On the basis of full studies of the research results and methods at home and abroad, we will put forward a more advanced small disturbance and power shifting stability program calculating method on the definition of static state stability (SSS), and a new kind of method based on increasing DC transient overload capability and meanwhile properly decreasing overload time. These propositions have been adopted by the Tian-Guang HVDC Engineering, the calculation results show that the SSS limit and power transmission capability will be increased obviously without further investment on the engineering.
机译:在对国内外研究成果和方法进行充分研究的基础上,我们将根据静态稳定度(SSS)的定义提出一种更先进的小扰动和功率转移稳定度程序计算方法,并提出一种新的方法。基于增加直流暂态过载能力,同时适当减少过载时间。这些建议已被天广直流输电工程采用,计算结果表明,无需对该工程进行进一步投资,SSS极限和输电能力将得到明显提高。