The end result of operating a feed water system through severe load transients is often times damage observed in the boiler feed pump. Damage, characterized by wear surface contact is produced as the pump operates in two phase flow or in more extreme cases dry. The classic transient and the effects on boiler feed pumps will be discussed along with the benefits in identifying and correcting the problem. A case study involving the boiler fee dpump in a 500 MW power plant is utilized to illustrate this transient behavior and impact on pump performance.
机译:通过剧烈的负载瞬变来运行给水系统的最终结果通常是锅炉给水泵中观察到的损坏的几倍。当泵以两相流运行或在更极端的情况下干燥时,会产生以磨损表面接触为特征的损坏。将讨论经典的瞬态信号及其对锅炉给水泵的影响,以及识别和纠正问题的好处。以一个涉及500 MW电厂锅炉费用下降的案例研究为例,说明了这种瞬态行为及其对泵性能的影响。