首页> 外文会议>World congress on medical physics and biomedical engineering;International congress of the IUPESM >Integration of Micro Fluidic Bio-chip Design and Automatic fluorescent Identification for Rapid Sperm Mobility Assessment
【24h】

Integration of Micro Fluidic Bio-chip Design and Automatic fluorescent Identification for Rapid Sperm Mobility Assessment

机译:微流体生物芯片设计与自动荧光识别的集成,可快速评估精子活动性

获取原文

摘要

Since male abnormality has now been reported to account at least thirty percent of couples with fertility problem. Therefore, distinguishing and classification of sperm has become more and more important, especially when Assisted Reproductive Technology (ART) like in vitro fertilization (IVF) is involved. However, traditional sperm sorting methods all requires manual selection, which is tedious and often cause sperm damage during the screen process. Although, new design from our recent study, seemed to point for a possibility to make these kind of MISS device capable of separating sperms into various mobility sub-class. In addition, the Hoechst 33258 and propidium iodide double staining results, also confirmed that the most motile and health sperm is indeed able to leave the laminar stream and being sorted out at outlet-h, with least dead sperm or debris. Meanwhile, we observed the dead sperm had been dominate from clear red stains and live sperm are not as active as is corresponded with more diffused blue stains. In order to confirm the real sorting situation, we counted the amount of sperm in collected sample by flow cytometry and tried to establish the statistic model. Though the flow cytometry, we could detect the sperm fluorescent distribution and count the size of sperm population. Nevertheless, /-test with 95% confidence level also shown significant difference in live/dead sperm ratio. Therefore, from the combined result among flow cytometry, fluorescent stain, and the statistic model test, it is confirmed that live sperms were able to cross the laminar stream created by the device and reach the sorting chamber with corresponding range from non-motile sperms to debris, as well as from living to dead ones. It is concluded that the proposed method is cost effective and is possible to serve as a protocol for rapid sperm quantitative assessment.
机译:由于据报道,男性异常至少占有生育问题的夫妻的百分之三十。因此,精子的区分和分类变得越来越重要,尤其是当涉及诸如体外受精(IVF)的辅助生殖技术(ART)时。但是,传统的精子分选方法都需要手动选择,这很繁琐,并且经常在筛选过程中造成精子损坏。尽管从我们最近的研究中得出的新设计似乎指出了使这类MISS设备能够将精子分为各种活动性子类别的可能性。此外,Hoechst 33258和碘化丙锭的双重染色结果还证实,最有活力和健康的精子确实能够离开层流并在出口h被分选出来,而死精子或碎屑最少。同时,我们观察到死精子主要来自清晰的红色污渍,而活精子的活性却不如分散的蓝色污渍活跃。为了确定真实的分选情况,我们通过流式细胞术对收集的样本中的精子数量进行了计数,并试图建立统计模型。通过流式细胞术,我们可以检测出精子的荧光分布并计算出精子的数量。尽管如此,置信水平为95%的I-test也显示了活/死精子比率的显着差异。因此,从流式细胞仪,荧光染色和统计模型测试的综合结果可以证实,活精子能够穿过该装置产生的层流并到达相应的范围,从非活动性精子到精子。碎片,以及从活到死的碎片。结论是,所提出的方法是成本有效的,并且可以用作快速精子定量评估的方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号