摘要

This paper presents an experimental study on the fire behavior of seven restrained RC beams strengthened with carbon fiber sheet (CFS) and provided with fire insulation. The influence of some parameters (i.e., axial and rotational restraint stiffness, thickness of the fire insulation, and load ratio) on the deformations and internal forces of the beams is analyzed. The test results indicate that: (a) for a restrained beam in fire, the maximum axial elongation decreases with increasing stiffness of the axial restraint, and increasing thickness of the fire insulation, while the maximum additional axial force increases with increasing stiffness of the axial restraint, and decreasing thickness of fire insulation. The maximum additional bending moment at the beam ends increases with decreasing thickness of the fire insulation, but on the whole the influence of the thickness of the fire insulation within the investigated range (10~20 mm [0.394~0.787 in]) is rather limited; (b) the additional axial force in a restrained beam recovers slightly during the cooling phase, while the additional bending moment at beam end of a restrained beam recovers significantly in the cooling phase; © the peak value of the bending moment of a strengthened and insulated beam occurs much later than in the case of an ordinary RC beam (i.e., without strengthening and fire insulation), while the maximum additional bending moment at beam end is lower; and (d) the influence of the rotational restraint stiffness on the maximum additional bending moments at beam ends is rather limited.
机译:本文对碳纤维薄板(CFS)加固并具有防火隔热性能的七种约束RC梁的耐火性能进行了实验研究。分析了一些参数(即轴向和旋转约束刚度,隔热材料的厚度以及负载比)对梁的变形和内力的影响。试验结果表明:(a)对于受约束的梁,其最大轴向伸长率随轴向约束的刚度增加,防火隔热厚度的增加而减小,而最大附加轴向力随轴向刚度的增加而增大。约束,并减少隔热层的厚度。随着隔热层厚度的减小,梁端的最大附加弯矩增加,但是总体上,隔热层厚度在研究范围内(10〜20 mm [0.394〜0.787 in])的影响是有限的; (b)约束梁的附加轴向力在冷却阶段略有恢复,而约束梁的梁端的附加弯矩在冷却阶段显着恢复; ©增强和绝缘梁的弯矩峰值出现的时间比普通RC梁(即没有增强和防火绝缘)的情况要晚得多,而梁端的最大附加弯矩更低; (d)旋转约束刚度对梁端最大附加弯矩的影响相当有限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号